RCT: In adults with STEMI-related cardiogenic shock, adding a microaxial flow pump to standard care reduced all-cause-mortality at 180 d.
Moller JE, Engstrom T, Jensen LO, et al. Microaxial Flow Pump or Standard Care in Infarct-Related Cardiogenic Shock. N Engl J Med. 2024 Apr 18;390(15):1382-1393. doi: 10.1056/NEJMoa2312572. Epub 2024 Apr 7.

BACKGROUND: The effects of temporary mechanical circulatory support with a microaxial flow pump on mortality among patients with ST-segment elevation myocardial infarction (STEMI) complicated by cardiogenic shock remains unclear.

METHODS: In an international, multicenter, randomized trial, we assigned patients with STEMI and cardiogenic shock to receive a microaxial flow pump (Impella CP) plus standard care or standard care alone. The primary end point was death from any cause at 180 days. A composite safety end point was severe bleeding, limb ischemia, hemolysis, device failure, or worsening aortic regurgitation.

RESULTS: A total of 360 patients underwent randomization, of whom 355 were included in the final analysis (179 in the microaxial-flow-pump group and 176 in the standard-care group). The median age of the patients was 67 years, and 79.2% were men. Death from any cause occurred in 82 of 179 patients (45.8%) in the microaxial-flow-pump group and in 103 of 176 patients (58.5%) in the standard-care group (hazard ratio, 0.74; 95% confidence interval [CI], 0.55 to 0.99; P = 0.04). A composite safety end-point event occurred in 43 patients (24.0%) in the microaxial-flow-pump group and in 11 (6.2%) in the standard-care group (relative risk, 4.74; 95% CI, 2.36 to 9.55). Renal-replacement therapy was administered to 75 patients (41.9%) in the microaxial-flow-pump group and to 47 patients (26.7%) in the standard-care group (relative risk, 1.98; 95% CI, 1.27 to 3.09).

CONCLUSIONS: The routine use of a microaxial flow pump with standard care in the treatment of patients with STEMI-related cardiogenic shock led to a lower risk of death from any cause at 180 days than standard care alone. The incidence of a composite of adverse events was higher with the use of the microaxial flow pump. (Funded by the Danish Heart Foundation and Abiomed; DanGer Shock ClinicalTrials.gov number, NCT01633502.).

Ratings
Specialty Area Score
Hospital Doctor/Hospitalists
Internal Medicine
Intensivist/Critical Care
Cardiology
Comments from MORE raters

Hospital Doctor/Hospitalists

Useful study on a new device showing mortality benefits despite several complications. Additional analysis on factors predisposing to complications would certainly be needed.

Intensivist/Critical Care

Microaxial flow pump, well known as Impella, is regularly used in cardiovascular emergency cases. Its effect is to reduce preload and antegrade flow, which could maintain systemic circulation effectively compared with former PCPS/ ECMO. The problem with Impella is high risk for bleeding that might cause serious complications related to a fatal accident. I agree that this device should be checked in multiple aspects to be used effectively.